Page 21
Implementation Steps
Utilizing the EdgeMarc GUI, follow the standard instructions (described in the user’s
guide) to enable the following on the EdgeMarc:
1.
Enable Network with VLAN functionality
o
Set LAN Port 2 to 802.1q framing.
Set LAN Ports 1, 3 and 4 to 802.1 framing.
o
Leave VLAN 2730 as management port:
IP Address: 192.168.1.1 with mask 255.255.255.0
o
Add a VLAN with:
ID: 200
IP address: 10.10.10.1 with mask 255.255.255.0
o
Add a VLAN with:
ID: 2
IP address: 10.0.0.1 with mask 255.255.255.0
o
Associate VLAN 2730 with LAN ports 1 and 4
o
Associate VLAN 200 with LAN port 2
o
Associate VLAN 2 with LAN port 3
When done, the VLAN screen should look similar to the following:
VLAN Configuration Page: